diff --git a/drivers/net/phy/dp83867.c b/drivers/net/phy/dp83867.c
index 1091a625bf4ceafe4dc237a24502f0fa1320b71f..14e9e8a946396aa4b7a2a1549a95461f47c80817 100644
--- a/drivers/net/phy/dp83867.c
+++ b/drivers/net/phy/dp83867.c
@@ -26,6 +26,12 @@
 
 /* Extended Registers */
 #define DP83867_CFG4            0x0031
+#define DP83867_CFG4_SGMII_ANEG_MASK (BIT(5) | BIT(6))
+#define DP83867_CFG4_SGMII_ANEG_TIMER_11MS   (3 << 5)
+#define DP83867_CFG4_SGMII_ANEG_TIMER_800US  (2 << 5)
+#define DP83867_CFG4_SGMII_ANEG_TIMER_2US    (1 << 5)
+#define DP83867_CFG4_SGMII_ANEG_TIMER_16MS   (0 << 5)
+
 #define DP83867_RGMIICTL	0x0032
 #define DP83867_STRAP_STS1	0x006E
 #define DP83867_RGMIIDCTL	0x0086
@@ -292,6 +298,18 @@ static int dp83867_config_init(struct phy_device *phydev)
 				     0);
 		if (ret)
 			return ret;
+
+		/* After reset SGMII Autoneg timer is set to 2us (bits 6 and 5
+		 * are 01). That is not enough to finalize autoneg on some
+		 * devices. Increase this timer duration to maximum 16ms.
+		 */
+		ret = phy_modify_mmd(phydev, DP83867_DEVADDR,
+				     DP83867_CFG4,
+				     DP83867_CFG4_SGMII_ANEG_MASK,
+				     DP83867_CFG4_SGMII_ANEG_TIMER_16MS);
+
+		if (ret)
+			return ret;
 	}
 
 	/* Enable Interrupt output INT_OE in CFG3 register */